Xmtd-2201 Manual Now
The XMTD-2201 is a member of the ubiquitous PID (Proportional-Integral-Derivative) temperature controller family, commonly found in industrial ovens, injection molding machines, packaging sealers, and laboratory equipment. Known for its 1/16 DIN size and dual-display LED interface, this unit bridges the gap between simple on/off thermostats and complex PLC-based systems.
| Parameter | Name | Description | Typical Value | | :--- | :--- | :--- | :--- | | | Alarm 1 Value | Temp to trigger alarm relay | 5.0 (°C above SV) | | P | Proportional Band | Aggressiveness of heating | 30.0 | | I | Integral Time | Eliminates steady-state error | 240 sec | | D | Derivative Time | Anticipates future error | 60 sec | | T | Cycle Time | For relay output (SSR = 2s, Relay = 20s) | 20 (relay) / 2 (SSR) | | SC | Sensor Correction | Offset for sensor error | 0.0 | | LCK | Lock Code | Locks menu (set to 0 to unlock) | 0 | xmtd-2201 manual
This article serves as a consolidated manual, covering the core aspects of the XMTD-2201: from terminal wiring to advanced PID tuning. Warning: Always disconnect mains power before wiring. The XMTD-2201 is typically rated for 100-240V AC. Use appropriate gauge wire for the relay output (usually 3A/250V AC resistive). The XMTD-2201 is a member of the ubiquitous